Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Neotrop. ichthyol ; 19(4)2021.
Article in English | LILACS-Express | LILACS, VETINDEX | ID: biblio-1485609

ABSTRACT

ABSTRACT The genus Cichla is a highly diverse group, with 16 species already described. Externally, some species are very similar and discriminating between them may be very difficult. Nevertheless, discrimination of fish stocks is essential for management purposes. Morphometric analyses of otoliths have been successfully used to distinguish species and fish stocks, especially in marine environments. This study evaluated whether sagittal otolith shape can be used to discriminate among the species Cichla temensis, C. monoculus, and C. orinocensis, as well as within populations of C. temensis in rivers of the Amazon. Shape indices and Fourier coefficients were used to describe the shape of the otoliths. Among the groups of species, the morphology of the sagittal otolith of C. temensis was totally distinct from the species C. monoculus and C. orinocensis. While among populations of C. temensis, individuals from the Negro and Jatapú Rivers were different, regardless of the methods used. These results confirm the ability to differentiate species and populations by using the morphology of otoliths. However, more research is needed to verify the role of genetic versus environmental and biotic effects, and thus be able to explain the discrimination observed in otoliths.


RESUMO O gênero Cichla é bastante diverso, com 16 espécies descritas. Algumas espécies são externamente muito similares e sua discriminação pode ser bastante difícil. Ao mesmo tempo, a discriminação de estoques pesqueiros é essencial para propostas de manejo. Análises morfométricas em otólitos têm sido utilizadas com sucesso para a distinção de espécies e estoques pesqueiros, principalmente em ambientes marinhos. Este estudo avaliou se o formato do otólito sagittal pode ser utilizado para discriminar entre espécies Cichla temensis, C. monoculus e C. orinocensis, bem como dentro de populações de C. temensis em diferentes rios amazônicos. Índices de forma e coeficientes de Fourier foram utilizados para descrever a forma dos otólitos. Dentre as espécies, a morfologia do otólito sagittal do C. temensis mostrou ser totalmente distinta das espécies C. monoculus e C. orinocensis. Enquanto no grupo das populações de C. temensis, os indivíduos dos rios Negro e Jatapú mostraram-se diferentes independente dos métodos utilizados. Esses resultados confirmam a capacidade de diferenciação de espécies e populações através da morfologia dos otólitos. No entanto, são necessárias mais pesquisas para verificar o papel dos efeitos genéticos em comparação aos efeitos ambientais e bióticos para explicar a discriminação observada nos otólitos.

2.
Arq. bras. oftalmol ; 77(6): 345-350, Nov-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-735807

ABSTRACT

Purpose: To compare the results of central corneal thickness (CCT) measurements obtained using optical low-coherence reflectometry (OLCR), Fourier domain optical coherence tomography (FD-OCT), and a Scheimpflug camera (SC), combined with Placido corneal topography. Methods: A total of 25 healthy subjects were enrolled in the present study, and one eye of each subject was included. A detailed ophthalmic examination was performed in all cases following CCT measurements with OLCR, FD-OCT, and SC. The results were compared using an ANOVA test. Bland-Altman analysis was used to demonstrate agreement between methods. Intra-examiner repeatability was assessed by using intraclass correlation coefficients (ICCs). Results: Statistically significant differences were observed between the results of the CCT measurements obtained using the three different devices (p=0.009). Significant correlations were found between OLCR and FD-OCT (r=0.97; p<0.0001), FD-OCT and SC (r=0.91; p<0.0001), and OLCR and SC (r=0.95; p<0.0001). The 95% limits of agreement (LOA) obtained from Bland-Altman plots were from -7.2 μm to 28.7 μm for OLCR versus FD-OCT, from -19.2 μm to 30.4 μm for OLCR versus SC, and from -42.6 to 32.3 μm for FD-OCT versus SC. Intra-examiner repeatability was excellent for each method, with ICCs >0.98. Conclusion: Although the results of CCT measurements obtained from these three devices were highly correlated with one another and the mean differences between instruments were comparable with the reported diurnal CCT fluctuation, the measurements are not directly interchangeable in clinical practice because of the wide LOA values. .


Objetivo: Comparar os resultados de medições de espessura corneana central (CCT ) obtidos com reflectometria óptica de baixa coerência (OLCR), tomografia de coerência óptica de domínio Fourier (FD-OCT ), e uma câmera Scheimpflug (SC), combinada com topografia corneana de placido. Métodos: Um olho de cada de 25 indivíduos saudáveis foram incluídos neste estudo. Um exame oftalmológico detalhado foi realizado em todos os casos após as medidas de CCT com OLCR, FD-OCT, e SC. Os resultados foram comparados por meio do teste ANOVA. Análise de Bland-Altman foi utilizada para demonstrar concordância entre os métodos. A repetibilidade intra-examinador foi avaliada por meio de coeficientes de correlação intraclasse (ICCs). Resultados: Foram observadas diferenças estatisticamente significativas entre os resultados das medidas de CCT obtidas a partir de três dispositivos diferentes (p=0,009). Foram encontradas correlações significativas entre OLCR e FD-OCT (r=0,97, p<0,0001), FD-OCT e SC (r=0,91, p<0,0001), e OLCR e SC (r=0,95; p<0,0001). Os limites de 95% de confiança (LOA) obtidos a partir de gráficos de Bland-Altman foram de -7,2 a 28,7 μm para OLCR contra FD-OCT, de -19,2 a 30,4 μm para OLCR contra SC, e de -42,6 a 32,3 μm para FD-OCT contra SC. A repetibilidade intra-examinador foi excelente para cada método com ICCs>0,98. Conclusões: Apesar de os resultados das medições CCT obtidos a partir destes três dispositivos terem sido altamente correlacionados entre si e as diferenças médias entre os instrumentos serem comparáveis à flutuação relatado da CCT diurna, as medições não são diretamente intercambiáveis na prática clínica em razão da largura dos valores limites de confiança. .


Subject(s)
Adolescent , Adult , Child , Female , Humans , Male , Middle Aged , Young Adult , Cornea/anatomy & histology , Corneal Pachymetry/instrumentation , Corneal Pachymetry/methods , Corneal Topography/methods , Tomography, Optical Coherence/methods , Analysis of Variance , Anatomy, Cross-Sectional , Biometry/instrumentation , Biometry/methods , Corneal Topography/instrumentation , Fourier Analysis , Observer Variation , Photography/instrumentation , Reference Values , Reproducibility of Results , Statistics, Nonparametric
SELECTION OF CITATIONS
SEARCH DETAIL